BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//CERN//INDICO//EN
BEGIN:VEVENT
SUMMARY:Front-end Readout ASIC Design for Ultra-fast Sensors Used in Muon 
 Detectors
DTSTART:20261126T130000Z
DTEND:20261126T140000Z
DTSTAMP:20261123T163400Z
UID:indico-event-5954@indico.kit.edu
CONTACT:timo.muscheid@kit.edu
DESCRIPTION:Speakers: Alexander Elsenhans\n\nAlexander Elsenhans will pres
 ent his PhD defense talk. The final presentation of his research will take
  place on December 10.\nAbstract:\nThis work presents the design\, impleme
 ntation\, and characterization of front-end ASICs for ultra-fast photon de
 tection in muon detector systems based on scintillator-wavelength shifting
  (WLS) fiber technology. The primary objective is to improve the spatial a
 nd temporal resolution of muon detection by leveraging advanced CMOS singl
 e-photon avalanche diode (SPAD) arrays with integrated time-to-digital con
 verters (TDCs). The physical principles of muon detection and SPAD operat
 ion\, as well as the state of the art in muon detectors and CMOS SPAD arra
 ys will be reviewed. Particular emphasis is placed on SPAD key parameters 
 and readout architectures\, with a comparison of analog silicon photomulti
 pliers (SiPMs) and digital SPAD-based solutions.\n \nTwo ASICs have been 
 developed:\n\n\nThe first\, ANDESPix\, is a fully integrated SPAD array im
 plemented in a 110 nm CMOS process\, comprising 1980 pixels with one TDC p
 er pixel. Each pixel incorporates two SPADs with passive quenching and dig
 ital signal generation. An SRAM-based delay-line TDC architecture enables 
 high integration density and continuous operation with zero-suppressed rea
 dout. Experimental characterization demonstrates effective fine-TDC bin wi
 dths of 100 ps to 150 ps. For pixels operating within locally linear regio
 ns of the TDC transfer characteristic\, an instrument response function (I
 RF) of approximately 270 ps was achieved.\n\n\n\n\nThe second ASIC\, PicoP
 articleCore\, implemented in a 16 nm FinFET technology\, explores compact 
 high-resolution TDC architectures based on gated ring oscillators\, achiev
 ing time resolutions in the picosecond range.\n\n\n \nPhoton pulse measur
 ements in scintillator-WLS systems using analog SiPMs reveal characteristi
 c features such as prompt signals\, afterpulsing\, and fiber-end reflectio
 ns\, providing insight for optimizing digital readout architectures.\n \n
 The results demonstrate that SPAD arrays with per-pixel TDCs enable detail
 ed time-resolved photon measurements and provide a viable approach for fut
 ure muon detector readout systems\, forming a basis for further developmen
 ts including hybrid 3D-integrated architectures.\n\nhttps://indico.kit.edu
 /event/5954/
LOCATION:Seminarraum EG (IPE)
URL:https://indico.kit.edu/event/5954/
END:VEVENT
END:VCALENDAR
